34 of 44 496339 Issue 1
Table 2. Menu 04 Zone Status - IDIS Zone Messages.
Display Meaning
NORMAL Circuit and anti tamper loops are closed.
CCT Alarm circuit loop is open.
A/T Anti tamper loop is open.
CCT A/T Alarm circuit and anti tamper loops are open.
MISSING IDIS module or device is missing (see "6. Fault Finding -
Error Messages").
Table 3. IDIS Handheld Programmer Error Messages
OUT OF RANGE The module is blank or incorrectly programmed.
Carry on and try to program the module. If you do
not succeed then use a new device and return the
original to the manufacturer.
NOT IDIS ZONE You have tried to program a zone number less than
9. Zones 1 to 8 are FSL zones.
NO DEVICE FOUND There is nothing connected to the programming pins
on the IDIS Expander card.
DEVICE FAULTY The system failed to program the device. Try again
to program the module. If you do not succeed then
use a new device and return the original to the
manufacturer.
FREQUENCY ERROR The device or module is not programmed correctly.
Try again to program the module. If you do not
succeed then use a new device and return the
original to the manufacturer.
NON SCANTRONIC The module is not a Scantronic IDIS device. The
module cannot be used.
c) Check the current readings from the module. Table 4 shows a list
of possible readings.
These readings can be viewed from a remote keypad as follows:
Start Menu 04 in Programming mode and select Zone Test.
Enter the zone number and the keypad displays one of the
messages in Table 2.
Press Enter twice and the keypad displays the appropriate reading.
Press Menu twice to escape.
Simple Test Method 8136