Error Messages
At various points in programming you may see error messages on the
display. The majority are self explanatory. The following list shows those that
are more obscure.
Configuration Checking Error Messages
The end station checks the configuration when you exit programming mode
or when you apply power. If the end station finds a configuration error during
power up it displays the message "CONFIGURATION ERROR CALL ENGI-
NEER" at the keypad. The panel is unusable until you cure the problem.
(Note that this will only occur if you have removed power from the end station
while in programming mode with a configuration error.)
The end station will not let you leave programming mode until you have cured
a configuration error.
The first line of the configuration checking error message always shows the
words "CHECK CONFIG". The second line of the display may show one of
the following:
AREA 04 NO P
Meaning: Area Not Assigned to Partition. In the example shown, Area 04 has
a zone type programmed, but has not been assigned to a Partition.
All programmed Areas must be Assigned to one Partition.
Action: Check Menus 32 and 35.
A2 IN P2 NO Z
Meaning: Empty Area Assigned to Partition. In the example shown Area 2
has been assigned to Partition 2, but there are no zones pro-
grammed to Area 2.
Action: Check Menu 32.
DUALPLY-V-DELAY
Meaning: You have enabled both Dual Ply Entry and Bell Delay, with Bell
Delay always also enabled. This combination is not allowed.
Action: Check Menus 67 and 53
DUALPLY-V-ABORT
Meaning: You have enabled both Dual Ply Entry and Alarm Abort at the same
time. Only one of these facilities should be enabled.
Action: Check Menu 67.
Error Messages 8136