496339 Issue 1 27 of 44
3. Wait while the remote PC establishes contact.
The display shows: CALL ANSWERED
followed by: SYSTEM UNDER
PC CONTROL
Other keypads in the system show: SYSTEM BEING
CONFIGURED!
When the Remote PC has completed downloading and signed off, the
display shows: DOWNLOAD
COMPLETE
followed by Menu 66.
Connecting a Local PC to Use Downloader (Menu 66).
The serial port can also by used as a link between a local PC and the sys-
tem. The local PC can run <DOWNLOADER> and change the system
programming in the same way as a remote PC.
Figure 13 shows the signals appearing at the pins of the serial port 9 pin
connector mounted on the end station PCB. The Figure also shows the pins
of a typical PC serial port, and the connections required in a cable to make a
local connection. Note that both ends of the cable should have female con-
nectors.
8136 Connecting to a Remote PC for the First Time