32 of 44 496339 Issue 1
FSL Zone Status Error Messages
Z01:FSL STATUS 1K9 (TROUBLE)
Meaning: FSL Loop Resistance Wrong. The loop resistance on one of the
FSL loops is above or below the normal threshold Level. Zones in
trouble will not prevent a user from setting the system, however, the
system displays the 'call engineer' message when the user tries to
set the system.
Action:
• Test FSL Zone status. Possible causes are loose or corroded
connections and high resistance.
• Check all wiring and connections associated with the zone(s) in
trouble.
IDIS Error Messages
ZONE 09 MISSING
Meaning: Menu 33 IDIS zones ‘MISSING’. The end station has tried to
initialise all valid IDIS modules/sensors and has failed.
Action:
See "IDIS Fault Finding".
IDIS Fault Finding
If the IDIS system is programmed and connected but either doesn't work
correctly or is inconsistent then this section describes steps you can take to
isolate the fault.
Work on one loop at a time to avoid confusion. Faults on one IDIS loop do
not affect other loops provided you have not linked the loops remote from the
panel.
Use the Simple Test Method described on the next page if you have just one
or two faults per loop. In this case it is best to assume at first that faults are
located at the modules the system reports as faulty.
Use the Thorough Test Method on the following page if there are more than
two faults per loop, or the initialisation is inconsistent from one time to the
next.
Before testing run Menu 33 Initialisation a few times. If there are any faults
then the display shows the highest zone number as the first fault. You can
see any other faults by pressing the up arrow key (the A key). Table 1 shows
the meaning of the messages that might be displayed.